Price of metal tube float flowmeter

airflowmeterf1799

DateTime 08/16/2026 Show 186
Operation principle of metal tube float flowmeter remote transmission module | River Doppler flowmeter manufacturer | Measurement of metal tube float flowmeter | Selection skills of flowmeter | Introduction to purge flowmeter|

Price:¥1.00Quantity:9999

Market Price:¥1.00Reduced Price:¥1.00

Effevtive Time:7/15/2026

Sale Address:SilverProduction Address:Silver automation instruments

Keywords:Operation principle of metal tube float flowmeter remote transmission module | River Doppler flowmeter manufacturer | Measurement of metal tube float flowmeter | Selection skills of flowmeter | Introduction to purge flowmeter|

Phone:QQ:Click:Wechat: +86 13512131526

Company:SILVER AUTOMATION INSTRUMENTS

『Price of metal tube float flowmeter』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

1. Operating principle of metal tube float flowmeter remote transmission module

The core of the operation of the metal tube float flowmeter remote transmission module is to collect float displacement signals through non-contact magnetic coupling, and output standardized electrical signals after signal conversion, realizing remote collection and transmission of flow data without contact with the measured fluid throughout the process.

1. Principle of magnetic coupling signal acquisition (1) Basic linkage logic 1 The float of the metal tube float flowmeter is embedded with a permanent magnetic steel inside. When the measured fluid flows through the conical metal tube, the float moves up and down along the axis with the change of flow rate. The displacement of the float is in a fixed linear relationship with the fluid flow rate. 2. The remote transmission module is installed in the protective shell outside the metal tube and is equipped with magnetic sensing components (such as Hall sensor array and reed switch group) inside. Through non-contact magnetic field coupling, the magnetic field displacement of the float magnetic steel is induced. 3. The magnetic sensing component converts the magnetic field displacement into a corresponding weak electrical signal, directly reflecting the real-time position of the float.

II. Signal Conversion and Remote Transmission Process (1) Signal Conditioning Calibration 1 The collected weak electrical signals will enter the signal conditioning circuit built into the remote transmission module to complete amplification, filtering, linear compensation, and convert the float displacement into standard flow values. 2. For different application scenarios, the conditioned s

Price of metal tube float flowmeter
ignals will be converted into universal remote transmission formats, including 4-20mA analog current signals, RS485 digital bus signals, HART protocol signals, etc. (2) Remote data transmission 1 The standardized signal after conversion is uploaded to the remote acquisition controller, DCS system, or SCADA platform through the BiSui matching cable, achieving off-site flow data monitoring and recording.

III. Key Usage Restrictions 1 The remote transmission module should avoid strong magnetic field environments (such as around large motors and transformers), otherwise it will interfere with the induction accuracy of the magnetic sensing components. 2. Explosion proof remote transmission modules should comply with the GB 3836 series explosion-proof standards (the latest version in 2023) and be suitable for measurement scenarios of flammable and explosive fluids. 3. During installation, it is necessary to ensure that the module is tightly attached to the outer wall of the metal tube to avoid magnetic field shielding deviation affecting measurement accuracy.

2. Measurement of metal tube float flowmeter

1. Sturdy all metal structure design type float flowmeter

2. Measuring tube indicator designed with independent concept

3. Stainless steel, Hastelloy alloy, titanium material can be selected.

PTFE material measurement system

4. Low pressure loss design

5. Short stroke and small structure with beam gauges, total instrument height of 250

6. Magnetic coupling structure ensures data transmission and more stable signal attenuation

7. Insulation or heat tracing jacket

8. Vertical, horizontal, and various installation methods are more suitable for different usa

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce
+86 15365082610